Wireless Temperature Sensor Specifications

Battery type CR2032 x1 (replaceable)
Battery life 2 to 85 months depending on usage and response delay setting
Range 700ft (210m) line of sight, 5ft from ground, default setting.
Beeper sound level 75dBA at 10cm
Temperature Operation range: -40°C (-40°F) to 85°C (185°F)
8-bit variant accuracy: +/-1°C typical, -2/+4°C max
13-bit variant accuracy: +/-0.4°C max
8-bit variant quantization level (resolution): 1°C (1.8°F)
13-bit variant quantization level (resolution): 0.02°C (0.036°F)
Logging and notification
Relative Humidity (Available only in 13-bit variant) +/-2% RH error, 10-bit resolution (0.12% step) Logging and notification
Size and weight Height: 1.7 inch (44 mm)
Width: 1.6 inch (41 mm)
Thickness: 0.33 inch (8.5 mm)
Weight: 0.5 oz (15 g)

FCCID: ZGW05. FCC Compliance Statement: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modification cautions to this device not explicitly approved by manufacturer could void your authority to operate this equipment.

Sensor with External Temperature Probe

External Temperature Sensor Specs

Battery type CR2450 x1
Battery life 3 years (typical)
Range 700ft (210m) line of sight (at default setting.)
Relative Humidity +/-2% RH error, 10-bit resolution (0.12% step)
Logging and notification
Temperature Operation range: -40°C (-40°F) to 85°C (185°F)
Sensor accuracy: +/-0.4°C typical
Sensor quantization level (resolution): 13-bit, 0.02°C step
Logging and notification
Dimensions Height: 0.6 inch (15.4 mm)
Width: 1.1 inch (27.6 mm)
Length: 2.7 inch (68.6 mm)

FCCID: ZGW07. FCC Compliance Statement: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modification cautions to this device not explicitly approved by manufacturer could void your authority to operate this equipment.

Wireless Ethernet Base

Wireless Ethernet Base Specs

Size and weight Height: 0.89 inch (22 mm)
Width: 2.15 inch (55 mm)
Depth: 1.88 inch (48 mm)
Weight: 1.9 oz (55 g) w/o AC adapter
Supported Wireless Sensor Tags Temperature + Humidity Sensor
Temperature + Humidity Logger
Sensor with External Temperature Sensor
Indicator lights Error light. Flashes when trying to configure itself to connect to the Internet (when acquiring IP address through DHCP). Rapidly flashes when trying to connect to web service.
Connected light. Lights up when connected to the cloud based web service.
Update light. Flashes when forwarding a Wireless Sensor Tag reading to the web service.
Login light. Lights up when connection is temporarily interrupted (when trying to re-connect to the web service)
Radio light. Gradually ramps up and down when radio is ready to receive sensor tag readings. Becomes solid when radio is transmitting a command to Wireless sensor tags.
Ethernet port 10Base-T
Requires DHCP server (Most routers/modems typically support DHCP)
Firewall must allow outgoing HTTP (port 80) and port 6667 connection
AC adapter (included) 100V~240V input 50/60Hz
5V output
300mA max current
User interface Web
iPhone/iPad App (Free)
Android App (Free)
Notification Email
Twitter
Apple Push Notification service on iPhone/iPad
Push notification on Android devices

FCCID: ZGW04. FCC Compliance Statement: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modification cautions to this device not explicitly approved by manufacturer could void your authority to operate this equipment.